Ulawulo lweNkqubo yoKhemesti kunye neBiotech

Umgangatho wamanzi, ukungaguquguquki kunye nokuthembeka yimicimbi ebalulekileyo kulo naliphi na iziko lophando lwe-biopharmaceutical, abantu ababandakanyeka kwi-bioproduction, ukufumanisa iziyobisi okanye iindawo ezinxulumene noko. Izixhobo ze-BOQU yinkokeli kunye nomzi mveliso omkhulu kumhlalutyi womgangatho wamanzi kunye nesenzi senzululwazi yekhemesti kunye ne-biotech e-China, njengengcali yokujonga umgangatho wamanzi, sinokujongana nayo nayiphi na imibuzo kunye neenkxalabo.

Amanzi asisiseko, kodwa yenye yezona zinto zisetyenziswayo kushishino lwamayeza. Ngokwesiqhelo, amanzi ayenziwa njenge-excipient, okanye asetyenziselwa ukwenziwa ngokutsha kweemveliso, ngexesha lokudityaniswa, ngexesha lokuveliswa kwemveliso egqityiweyo, okanye njengearhente yokucoca yokuhlanjwa kweenqanawa, izixhobo kunye nezinto zokuqala zokupakisha, njl. Isicelo sebhayoloji, iintlobo ezininzi zahlulwe: Amanzi acocekileyo, Amanzi okuTofa, Amanzi eHemodialysis, Amanzi angcolileyo, Amanzi acocekileyo, Amanzi acocekileyo ngenaliti, Amanzi eBacteriostatic ngenaliti, Amanzi angenanzala okunkcenkceshela, Amanzi acocekileyo okuphefumla.

Kwikhemesti kunye nenkqubo yolawulo lwe-biotech, i-BOQU liqabane lakho elithembekileyo. Sinokubonelela ngesisombululo esikhawulezileyo nesobuchule semibuzo yakho ecaleni kwakho. Mhlawumbi uya kubuza: ngoba? Ngenxa yokuba i-BOQU yakha ilebhu yokuqala yokushisa okuphezulu kwe-pH, i-ORP, ukuqhuba kunye nokuchithwa kwenjini yeoksijini, ikwangowona mveliso mkhulu eTshayina. Iwaranti ye-VBQ series yiminyaka emithathu. Apha ngezantsi kukho itafile yokuthelekisa yeMETTLER TOLEDO kunye neHAMILTON.

Thelekisa itafile neMETTLER TOLEDO kunye neHAMILTON pH Sensor

Uluhlu lwe-pH

Ubushushu (℃)

Uxinzelelo

Ukuxhathisa kwangaphakathi

Indawo yeZero

Ithambeka

Umzekelo

Igama lebrand

0 ~ 14

0 ~ 130

0.6

250

7 ± 0.5

> 95

pH5805 / S7

IBOQU

0 ~ 14

0 ~ 140

0.6

250

7 ± 0.5

> 95

KwiPro2000

METTLER TOLEDO

0 ~ 14

0 ~ 130

0.6

250

7 ± 0.5

> 95

ICHEMOTRDDE

IHAMILTON

Ukusetyenziswa kobushushu be-pH woluvo

  IBOQU
pH5806 uthotho
METTLER TOLEDO
InPro3250 uthotho
IHAMILTON
Uthotho lwe-EASYFERM Plus
Iifayile Ukuchaneka okuphezulu
Ilungele imeko engqongqo
Zimbalwa izondlo
Ijeli eqinileyo
Isinxibelelanisi: VP / K8S / S8 / wire lead
Ukuchaneka okuphezulu
Ilungele imeko engqongqo
Zimbalwa izondlo
Ijeli eqinileyo
Isinxibelelanisi: VP / K8S / S8
Ukuchaneka okuphezulu
Ilungele imeko engqongqo
Zimbalwa izondlo
Ijeli eqinileyo
Isinxibelelanisi: VP / K8S / S8
Ukusetyenziswa Itanki yokuvumba
Biotechnology
Icandelo lezamayeza
Itekhnoloji yokutya nesiselo
Isitashi oluludaka
 
Itanki yokuvumba
Biotechnology
Icandelo lezamayeza
Ukutya nesiselo
Ukuveliswa kwemichiza
Iphepha, isitashi somgubo, ukunyibilikisa ipetroleum, njl.
Itanki yokuvumba
Biotechnology
Icandelo lezamayeza
Icandelo lezemichiza

Itheyibhile yokuthelekisa neMETTLER TOLEDO kunye neHAMILTON yokuchithwa kweSensor yeSensor

YENZA uluhlu

Ubushushu (℃)

Uxinzelelo

Izinto eziphathekayo

Isinxibelelanisi

Uxilongo (mm)

Umzekelo

Igama lebrand

6ppb ~ 20ppm

0 ~ 130

0.6

I-SS316L

VP

12 okanye 25

INJA-208FA

IBOQU

6ppb ~ 20ppm

0 ~ 140

0.6

I-SS316L

VP

12 okanye 25

KwiPro6800

METTLER TOLEDO

10ppb ~ 40ppm

0 ~ 130

0.4

I-SS316L

I-VP / T82D4

12 okanye 25

INTSHUMAYELI

IHAMILTON

Ukusetyenziswa Ubushushu High ichithwe Oxygen woluvo

  IBOQU
INJA-208FA
METTLER TOLEDO
KwiPro6800
IHAMILTON
INTSHUMAYELI
Iifayile Ukuchaneka okuphezulu
Ilungele imeko engqongqo
Isinxibelelanisi: VP
Ukuchaneka okuphezulu
Ilungele imeko engqongqo
Isinxibelelanisi: VP
Ukuchaneka okuphezulu
Ilungele imeko engqongqo
Isinxibelelanisi: VP / T82D4
Ukusetyenziswa Itanki yokuvumba
Biotechnology
Icandelo lezamayeza
Ukutya nesiselo, njl
Itanki yokuvumba
Biotechnology
Icandelo lezamayeza
Ukutya nesiselo, njl
Itanki yokuvumba
Biotechnology
Icandelo lezamayeza
Ukutya nesiselo, njl
https://www.boquinstruments.com/pharmacy-biotech-process-control/
Pharmacy & Biotech Process Control1