Yeyiphi eyona mitha ye-pH echasene nokuqhuma kwemizi-mveliso engcono kakhulu?

I-EXA300 Two-Wire pH/ORP Analyzer sisisombululo sokujonga esikrelekrele esikwi-intanethi esenzelwe iimeko zoshishino ezinzima. Yenziwe kwaye yenziwa yiShanghai Boqu Instrument Co., Ltd., idibanisa itekhnoloji yanamhlanje kunye neempawu zokhuseleko eziqinileyo ukuze inike umlinganiselo we-pH/ORP ochanekileyo, othembekileyo, nongenakugcinwa.

Iimpawu eziphambili kunye neenzuzo

1.Uyilo Olukhuselekileyo Nolungenaziqhushumbisi

  • Iyahambelana nemigangatho ye-GB3836.1-2010 kunye ne-GB3836.4-2010, ilinganisweEx ia IIC T4Ga‌.
  • Ifanelekile kwiindawo ezinobungozi ezinamaqondo obushushu aphantsi ukusuka kwi-20 °C ukuya kuma-55 °C‌.

2.Uluhlu Lokulinganisa Oluphezulu Nolubanzi

  • i-pH:‌ 0.00–14.00 (± 0.05 ukuchaneka kwe-pH)
  • I-ORP:-2000 mV ukuya kwi-2000 mV (ukuchaneka kwe-±1 mV)
  • Ubushushu:‌Pt1000: 0.0 °C–130.0 °C / NTC10k: -30.0 °C–100.0 °C (ukuchaneka kwe-±0.5 °C)

3.Imveliso yeengcingo ezimbini ezingama-4–20 mA kunye nokusetyenziswa kwamandla aphantsi

  • Isiphumo se-current-loop esisodwa se-4–20 mA sokudibanisa ngaphandle komthungo neenkqubo ze-PLC, i-DCS, okanye ze-SCADA.
  • Ukusetyenziswa kwamandla aphantsi kakhulu (0.66 W) kuxhasa ukusebenza kwexesha elide nokuba kufakwe kude okanye kufakwe amandla abuthathaka.

4.Ulwakhiwo Oluqinileyo kunye Nokusetyenziswa Okulula

  • Indlu ye-aluminium eyenziwe nge-die-cast eneIP65ukhuseleko ekungeneni kothuli namanzi.
  • Ubukhulu obuncinci (144 mm × 144 mm × 147 mm) kunye neendlela ezahlukeneyo zokufakela: ukufakwa okufakwe ngaphakathi, ukufakwa kwimibhobho, udonga olusecaleni, ukufakwa kwe-top-flange, ukuntywiliselwa, kunye nokufakelwa kwe-flow-through.

5.Ukusebenza okulula ukuSebenzisa kunye noLungiso oluHlakaniphileyo

  • Isibonisi se-LCD esicacileyo esinokuhamba ngamaqhosha amahlanu ukuze kulungiselelwe ngokukhawuleza, kulinganiswe, kwaye kuhlolwe.
  • Iindlela ezininzi zokulinganisa: ngesandla, i-auto-cal enamachaphaza amabini, i-auto-cal enamachaphaza amathathu, kunye namaqela e-buffer anokulungiswa (imigangatho ye-JJG/NIST).
  • Isalathisi semeko ye-electrode ngexesha langempela (egqwesileyo/eqhelekileyo/embi) kunye nokulungiswa kwendlela yokulungisa ukuze kuphume imveliso ezinzileyo ngexesha lokulungiswa kwesensor.

Imeko ezifanelekileyo zokusetyenziswa
I-EXA300 yenzelwe ukujonga rhoqo iinkqubo ezifuna kakhulu:

  • Ukwenziwa kweeKhemikhali kunye namaYeza- Ulawulo oluchanekileyo lwe-pH/ORP kwimikhumbi yokusabela, ukubiliswa, kunye nemijelo yokucoca.
  • Ukuveliswa koMbane kunye noNyango lwaManzi- Ukubeka esweni amanzi okusela kwibhoyila, imijikelo yokupholisa, kunye nokukhutshwa kwamanzi amdaka.
  • Isinyithi kunye ne-Electroplating- Umlinganiselo we-ORP weempendulo ze-redox kunye nokulandelela uxinano lwe-metal-ion.
  • Imveliso yokutya neziselo- Uqinisekiso lwe-pH kwiinkqubo zomgangatho wemveliso kunye nezococeko.
  • Ukubeka iliso kwiNdalo- Ukuhlolwa kwamanzi amdaka, imilambo, kunye nenkunkuma yemizi-mveliso ngexesha langempela ukuze kuhlangatyezwane nemigangatho yolawulo.

Kutheni ukhetha i-EXA300?

Iqinisekisiwe yoKhuselekoUvavanyo oluchasene nokuqhuma luqinisekisa ukusebenza kwiindawo ezinobungozi.
Xhuma kwaye udlale- Ucingo olulula (oluchazwe yi-terminal-block) kunye nokufakelwa kwe-electrode ngokukhawuleza.
Ukugcinwa Okuphantsi- Indlu evaliweyo, amandla okuseta kwakhona ifektri, kunye nezikhokelo zokusombulula iingxaki ezibanzi zinciphisa ixesha lokungasebenzi.
Inkxaso yeHlabathiIxhaswa yinkonzo yobugcisa yeShanghai Boqu Instrument kunye nenethiwekhi yasemva kokuthengisa (unxibelelwano: 021-33897320).

Iinkcukacha zobugcisa ngokukhawuleza

  • Ukunikezwa Amandla:‌14–28 VDC
  • Isiphumo:4–20 mA eneengcingo ezimbini
  • Umthamo woMthwalo:Iyahambelana neemodyuli zokufaka ze-PLC/DCS eziqhelekileyo
  • Indawo yokusebenza:-20 °C ukuya kuma-40 °C, ≤95 % RH (ayifumi)
  • Ubunzima:1.35 kg
Bhala umyalezo wakho apha uze uwuthumele kuthi

Ixesha leposi: Matshi 31-2026