Ukulinganiswa kwe-pH kudlala indima ebalulekileyo kumashishini ahlukeneyo, kuquka ukwenziwa kwemveliso, uphando, kunye nokubeka esweni okusingqongileyo. Xa kufikwa kukulinganiswa kwe-pH kwiindawo ezinobushushu obuphezulu, kufuneka izixhobo ezikhethekileyo ukuqinisekisa ukufundwa okuchanekileyo nokuthembekileyo.
Kule posi yebhlog, siza kujonga umahluko phakathi kweeprobe ze-pH ezinobushushu obuphezulu kunye neeprobe eziqhelekileyo. Siza kuhlola iimpawu ezikhethekileyo, usetyenziso, kunye neenzuzo zeeprobe ze-pH ezinobushushu obuphezulu, sikhanyise ngokubaluleka kwazo kumashishini athile.
Ukuqonda umlinganiselo we-pH:
Iziseko zokulinganisa i-pH:
Ukulinganisa i-pH yinkqubo yokufumanisa ubumuncu okanye i-alkalinity yesisombululo. Isikali se-pH, esiqala kwi-0 ukuya kwi-14, sisetyenziselwa ukubonisa uxinano lwee-ion ze-hydrogen kwisisombululo. Ixabiso le-pH eliyi-7 lithathwa njengelingathathi cala, amaxabiso angaphantsi kwe-7 abonisa ubumuncu kwaye amaxabiso angaphezulu kwe-7 abonisa ubumuncu.
Ukulinganiswa kwe-pH ngokuchanekileyo kubalulekile kumashishini ahlukeneyo, njengoko kubonelela ngolwazi olubalulekileyo malunga neempendulo zeekhemikhali, umgangatho wemveliso, kunye neemeko zokusingqongileyo.
Indima yee-pH Probes:
Iiprobe ze-pH, ezaziwa ngokuba zii-pH sensors, zizixhobo ezibalulekileyo zokulinganisa amanqanaba e-pH ngokuchanekileyo. Iprobe eqhelekileyo ye-pH iqulathe i-electrode yeglasi kunye ne-electrode yesalathiso. I-electrode yeglasi iyaziva utshintsho kwi-hydrogen ion concentration, ngelixa i-electrode yesalathiso inika amandla okubhekisa azinzileyo.
Ezi probes zisetyenziswa kakhulu kumashishini afana nokutya neziselo, amayeza, unyango lwamanzi, kunye nezolimo, phakathi kwezinye.
IiProbe ze-pH eziqhelekileyo: 0-60 ℃
Iimpawu kunye noYilo:
Iiprobe ze-pH eziqhelekileyo zenzelwe ukusebenza ngokufanelekileyo kubushushu obahlukeneyo. Zihlala zakhiwe ngezinto ezibonelela ngokumelana kakuhle neekhemikhali kunye nokuqina.
Ngokubanzi, ubushushu bezi probe ze-pH buphakathi kwe-0-60 degrees Celsius. Zihlala zakhiwe ngezinto ezinika ukumelana okuhle kweekhemikhali kunye nokuqina.
I-element yokuva ye-probe ye-pH eqhelekileyo yenziwe nge-membrane yeglasi ebhityileyo esebenzisana nesisombululo esilinganiswayo. I-electrode yokubhekisa iqulethe i-junction enemingxuma evumela ii-ion ukuba zihambe, igcina amandla okubhekisa azinzileyo.
Izicelo kunye nemida:
Iiprobe ze-pH eziqhelekileyo zisetyenziswa kakhulu kumashishini apho ubushushu buhlala bukwimeko eqhelekileyo yokusebenza. Ezi probe zifanelekile kwizicelo ezifana nohlalutyo lwelebhu, ukujonga umgangatho wamanzi, kunye nonyango lwamanzi amdaka.
Nangona kunjalo, zinemida xa kufikwa ekulinganiseni i-pH kwiindawo ezinobushushu obuphezulu. Ukuveza ii-pH probes eziqhelekileyo kubushushu obugqithisileyo kunokubangela ukuncipha kokuchaneka, ukuncipha kwexesha lokuphila, kunye nomonakalo onokubakho kwiindawo ze-probe.
Iiprobe ze-pH zobushushu obuphezulu ze-BOQU: 0-130 ℃
Ukongeza kwizinto eziqhelekileyoii-pH probes, I-BOQU ikwabonelela ngeengcaliIiprobe ze-pH zobushushu obuphezuluukuhlangabezana neemfuno eziphezulu.
Uyilo oluKhethekileyo kunye noLwakhiwo:
Iiprobe ze-pH ezikwiqondo eliphezulu zenzelwe ngokukodwa ukumelana namaqondo obushushu aphezulu ngaphandle kokuphazamisa ukuchaneka nokuthembeka. Ezi probe ziquka izixhobo eziphambili kunye neendlela zokwakha ukuqinisekisa ukusebenza kwazo kwiimeko ezimandundu.
Into yokuva yeprobe ye-pH yobushushu obuphezulu inokwenziwa ngezinto ezikhethekileyo ezinokumelana noxinzelelo lobushushu kwaye zigcine uzinzo.
Iingenelo kunye neenzuzo:
- Ukumelana nobushushu obuphezulu:
Iiprobe ze-pH ezikwiqondo eliphezulu ezivela kwi-BOQU zenzelwe ukumelana namaqondo obushushu afikelela kwi-130 ℃. Ziquka izixhobo ezikhethekileyo kunye neendlela zokwakha eziqinisekisa ukusebenza kwazo kwiimeko zobushushu obugqithisileyo.
Olu xhathiso lobushushu oluphezulu luvumela ukulinganiswa kwe-pH okuchanekileyo nokuthembekileyo nakwiindawo ezifuna ubushushu obuphezulu.
- Ukusebenza Okungenasondlo:
Iiprobe ze-BOQU's High Temp pH zinejeli ye-dielectric ethintela ubushushu kunye nezakhiwo ze-dielectric double liquid junction eziqinileyo. Ezi zakhiwo zisusa isidingo se-dielectric eyongezelelweyo kwaye zifuna ulondolozo oluncinci.
Oku kunciphisa ixesha lokungasebenzi kwaye kuqinisekisa ukulinganiswa kwe-pH okuqhubekayo nokungaphazanyiswayo kwizicelo zobushushu obuphezulu.
- Uyilo lweSokhethi yeMisonto eSebenza ngeendlela ezininzi:
Iiprobe ze-pH ezikwi-High Temp ezivela kwi-BOQU ziyilwe ngeesokhethi ze-K8S kunye ne-PG13.5 thread. Olu yilo luvumela ukutshintshwa lula nayo nayiphi na i-electrode yangaphandle, nto leyo ebonelela ngokuguquguquka kunye nokuhambelana neenkqubo ezahlukeneyo zokulinganisa i-pH.
Abasebenzisi banokudibanisa ngokulula iiprobe ze-BOQU's High Temp pH kwiisetingi zabo ezikhoyo ngaphandle kwesidingo sotshintsho olukhulu.
- Ukuqina Okuphuculweyo Ngesingxobo Esingenasici:
Iiprobe ze-BOQU ze-High Temp pH zenziwe nge-316L stainless steel sheath. Olu maleko longezelelweyo lokukhusela luphucula ukuqina nokuthembeka kweeprobe, nto leyo eyenza zifaneleke ukufakwa kwiitanki nakwii-reactor.
Isingxobo sentsimbi engagqwaliyo sibonelela ngokumelana nokugqwala kwaye siqinisekisa ukusebenza ixesha elide kwiindawo zoshishino ezinzima nezifuna amandla.
Ukusetyenziswa kweeProbes ze-pH zoBushushu obuPhezulu:
Iinkqubo zoshishino:
Iiprobe ze-pH ezikwiqondo lobushushu eliphezulu zidlala indima ebalulekileyo kwiinkqubo ezahlukeneyo zoshishino. Umzekelo, kwishishini le-petrochemical, apho ukusabela kobushushu obuphezulu kuxhaphake khona, ukulinganisa i-pH ngokuchanekileyo kubalulekile ekujongeni nasekulawuleni iinkqubo zeekhemikhali.
Ezi probes zikwasetyenziswa kwiinkqubo zokuvelisa ezisebenzisa ubushushu obuphezulu ezifana nokuvelisa iglasi, ukunyibilikisa isinyithi, kunye nokwenza iiceramics. Kwicandelo lokuvelisa amandla, iiprobes ze-pH ezisebenzisa ubushushu obuphezulu zisetyenziswa kwizikhululo zamandla ukujonga i-pH yamanzi okupholisa, amanzi okusela ebhoyila, kunye nezinye iinkqubo ezibalulekileyo.
Uphando nophuhliso:
Iiprobe ze-pH ezikwiqondo eliphezulu zifumana usetyenziso kwiindawo zophando nophuhliso. Zizixhobo ezixabisekileyo zokwenza iimvavanyo ezibandakanya amaqondo obushushu aphezulu. Abaphandi abafunda nge-catalysis yobushushu obuphezulu, ukuhlanganiswa kwezinto, kunye nokuzinza kobushushu badla ngokuxhomekeka kwezi probe zikhethekileyo ukujonga utshintsho lwe-pH ngokuchanekileyo.
Ngokusebenzisa iiprobe ze-pH ezikwiqondo eliphezulu, izazinzulu zinokufumana ulwazi oluxabisekileyo malunga nokuziphatha kunye neempawu zezinto kunye neempendulo zeekhemikhali kubushushu obuphezulu.
Ukukhetha i-pH Probe efanelekileyo kwiimfuno zakho:
Xa ukhetha i-pH probe, kubalulekile ukuqwalasela ezi zinto zilandelayo:
Izinto ekufuneka ziqwalaselwe:
Xa ukhetha phakathi kweprobe ye-pH yeTemp ephezulu kunye neprobe eqhelekileyo, kufuneka kuqwalaselwe izinto ezininzi. Iimfuneko zomgangatho wobushushu zibaluleke kakhulu.
Misela ubushushu obuphezulu ekufuneka kwenziwe kubo umlinganiselo we-pH kwaye uqinisekise ukuba iprobe ekhethiweyo iyakwazi ukumelana nezo meko. Ukuchaneka nokuchaneka kufuneka kuqwalaselwe, kunye neemfuno zokuqina kunye nokugcinwa kweprobe.
Ukubonisana kunye nobungcali:
Kucetyiswa ukuba udibane neengcali zokulinganisa i-pH okanye abavelisi bezixhobo, njenge-BOQU, ukuqinisekisa ukuba kukhethwa i-pH probe efanelekileyo kwizicelo ezithile.
Banokubonelela ngesikhokelo sokukhetha iprobe efanelekileyo ngokusekelwe kwiimfuno zobushushu, iimfuno zokuchaneka, kunye nokuqwalaselwa kwebhajethi.
Amagama okugqibela:
Ukulinganisa i-pH ngokuchanekileyo kubalulekile kumashishini amaninzi, ingakumbi lawo asebenza kwiindawo ezinobushushu obuphezulu. Nangona ii-pH probes eziqhelekileyo zisebenza kakuhle kwiindawo ezininzi, zisenokungaphumeleli xa kufikwa kwiindawo ezinobushushu obuphezulu.
Iiprobe ze-pH ezikwiqondo eliphezulu, ngoyilo lwazo olukhethekileyo kunye nolwakhiwo lwazo, zibonelela ngokusebenza okuphezulu, ukuhlala ixesha elide, kunye nokuthembeka kwezi meko zinzima.
Ngokuqonda umahluko phakathi kweeprobe ze-pH ezikwiqondo eliphezulu kunye neeprobe eziqhelekileyo, amashishini angenza izigqibo ezinolwazi aze akhethe iprobe ye-pH efanelekileyo kwiimfuno zawo ezithile.
Ixesha lokuthumela: Juni-22-2023











